| AO-MB51314-AFP5KW-EU-JK | AO-MB51300-AFP5KW-EU-JK | AO-MB51280-AFP5KW-EU-JK | |
| BATTERY TECHNICAL SPECIFICATION | |||
| Battery model | MB51314-100A-HWB | MB51300-100A-HWB | MB51280-100A-HWB |
| Number of batteries | 1 | ||
| Battery Energy | 16076.8Wh | 15360Wh | 14336Wh |
| Battery Capacity | 314AH | 300AH | 280AH |
| Dimension L×D×H | 450×300×990 | ||
| Battery Type | LiFePO4 | ||
| Battery Rated Voltage | 51.2V | ||
| Battery Working Voltage Range | 44.8~57.6V | ||
| Maximum Charging Current | 100A | ||
| Maximum Discharging Current | 100A | ||
| DOD Designed Life-span | >10000 Cycles @0.2C/25℃ Charging/Discharging. | ||
| INVERTER TECHNICAL SPECIFICATION | |||
| INVERTER TECHNICAL | AFP4850S100-H | ||
| Solar Charging | |||
| Solar Charge Type | MPPT | ||
| Maximum PV input power | 7500W | ||
| Solar Charging Current Range (Settable) | 0~100A | ||
| Maximum PV input current | 30A | ||
| Max.PV Open -Circuit Voltage | 500Vdc | ||
| MPPT Voltage Range | 60~450Vdc | ||
| Grid Charging | |||
| Maximum charge current(can be set) | 80A | ||
| Charge current error | ±5 Adc | ||
| Charge voltage range | 40~58Vdc | ||
| Circuit breaker specifications | 40A | ||
| Overcharge protection | Alarms and shuts off charging after 1minute | ||
| Grid Output (AC) | |||
| Rated Output Power | 5000w | ||
| Maximum Output Current | 21.7A | ||
| Frequency | 50Hz | ||
| Rated voltage | 230Vac | ||
| BATTERY INVERTER OUTPUT | |||
| Rated Output Apparent Power | 5000VA | ||
| Rated Output Active Power | 5000W | ||
| Peak Power | 10000VA | ||
| Power Factor | 1 | ||
| Rated Output Voltage (Vac) | 230Vac | ||
| Frequency | 50Hz | ||
| Output Voltage Tolerance | ±5% | ||
| Max.Efficiency | >92% | ||
| GENERAL DATA | |||
| Communication | RS485/CAN/WIFI | ||
| Storage time/temperature | 6months @25℃;3 months @35℃;1 months @45℃; | ||
| Charging temperature range | 0-45℃ | ||
| Discharging temperature range | -10-45℃ | ||
| Operation Humidity | 5%-85% | ||
| Nominal Operation Altitude | <2000m | ||
| Cooling Mode | Force-Air Cooling | ||
| Noise | 60dB(A) | ||
| Ingress Protection Rating | IP20 | ||
| Recommended Operation Environment | Indoor | ||
| Installation Method | Vertical | ||

Precautions
•No matter what the charging model is, once the temperature of the cell is above the absolute charging temperature, charging should be stopped.
• Please check the orientation of the positive and negative terminals before packaging.
•Connect the terminal or wire to the battery module, and pay attention to insulation to prevent short circuits.
• When not in use for a long time, the battery should be stored in a cool and dry place (<35°C, 30%~50% SOC, charge and discharge once every 3 months).
• Do not place the battery in direct sunlight or a heat source.
• Do not wear metal jewelry (such as rings, watches, accessories, etc.) when handling the battery unit.
Prohibited Matters
Do not charge beyond the maximum charging rate.
Do not disassemble or modify the battery.
Do not throw or hit the battery.
Do not pierce the battery with sharp objects (such as nails, knives, pens, or electric drills).
Do not mix with other types of batteries or modular units.
Do not excessively squeeze the battery during use.
Do not place the battery in a high temperature greater than 60°C.
Do not use conductive materials to connect the positive and negative terminals (such as metals, and wires).